Customization: | Available |
---|---|
Type: | Drainage Container/Tube |
Material: | Plastic |
Still deciding? Get samples of US$ 1/Piece
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
2000ml Urine Bag with Push-Pull Valve
Expertly crafted with unparalleled precision, the 2L Urine Bag featuring a Push-Pull Valve emerges as a critical healthcare solution for urine collection needs. Its elegant and robust design ensures unwavering reliability and efficiency, making it an indispensable choice in medical care.
Our Medical Urine Catheter Bags are meticulously designed for individuals managing urinary incontinence, retention, post-surgical catheterization, and various other health conditions. They provide peace of mind with unmatched comfort, empowering users to manage their health gracefully and confidently.
Featuring clearly marked, easy-to-read graduation scales, our Urine Bag allows for swift and precise urine volume assessment. This exactness greatly aids in effective health monitoring, ensuring optimal care management.
Ingeniously engineered with a push-pull valve, this urine catheter bag offers effortless emptying while minimizing spillage risk, enhancing user safety and convenience with its intuitive design.
Designed to be latex-free, this product assures safe usage for everyone, significantly reducing allergic reactions while maximizing comfort and user satisfaction.
Our comprehensive urine bag design is imbued with advanced features to provide unrivaled functionality:
A durable 2L Urine Bag Body, crafted to endure frequent use while preserving its structural integrity.
Kink-resistant inlet tube, guaranteeing smooth flow and consistent, hassle-free performance.
A secure adapter equipped with a cap ensures steadfast connections, enhancing user confidence and reliability.
State-of-the-art anti-reflux flutter valve to prevent backflow, safeguarding users from any potential complications.
User-centric Push-Pull Valve, designed for effortless operation and prioritizing user convenience to the utmost.
ivdivual package | 10pcs/poly bag | 250pcs/carton | 58X34X38cm | G.W 9.5kg | N.W 9.5kg |
Since its inception in 2017, Changzhou CareU Medical Instruments Co., Ltd. has swiftly ascended to become a formidable force in the global medical trade arena. Nestled in the dynamic Zhenglu Town of Changzhou city, within the prestigious Jiangsu province, we are uniquely poised to benefit from the town's rich heritage in the medical industry. Our state-of-the-art facilities include a sophisticated 100,000-level purification workshop alongside internationally renowned production equipment, ensuring we uphold the highest quality standards with unwavering dedication. This steadfast commitment guarantees that every product we offer epitomizes unparalleled excellence and innovation, setting new benchmarks in the industry.
Changzhou CareU Medical Instruments Co., Ltd. is recognized as a beacon of distinction in both manufacturing and sales, with a specialized focus on premium feeding medical equipment, urine drainage bags, precision medical components, and gynecological products. From expertly designed washing hand brushes to precision-crafted cervical swabs and comprehensive disposable gynecological examination kits, we are driven by our core principle of 'customer first, forge ahead.' This guiding principle inspires us in our relentless pursuit to deliver extraordinary products and services, consistently surpassing the stringent quality benchmarks of the medical industry. Our dedication ensures that every offering not only meets but exceeds expectations, fostering trust and satisfaction among our clientele.
1. Begin your installation journey by carefully washing your hands with soap and water. This step upholds the highest hygiene standards, ensuring your safety is never compromised during the process.
2. Gently remove the protective cap from the Medline Catheter Bag, guaranteeing all components are kept in a pristine, sterile state.
Ensure the drainage spout is tightly closed to prevent any leakage, thereby maintaining the integrity and reliability of the product.
3. Use an alcohol-saturated pad or a similar cleaning tool,
to thoroughly clean both the tubing connector end and the catheter end. Afterward, connect the catheter to the drain bag tubing
connector for a secure fit, ensuring a dependable and confident connection.
4. Dispose of all excess materials, such as packaging and alcohol pads,
responsibly, in alignment with environmental and safety guidelines.
5. Conclude the installation process by washing your hands again with soap and water, reinforcing hygiene practices to protect against any remaining contamination.
Exercise caution with sharp objects when opening the package to avoid compromising the product's integrity or risking personal safety.
This device is intended for single-use only. Reusing it increases infection risk, so always opt for a new one. Safeguard your health by adhering strictly to the single-use guideline.
Store the product in a cool, dry place with a temperature range between 15°C and 25°C to ensure its longevity and optimal performance.